Similar Cases: Steam Turbine Failure and Explosion Catastrophic Failure of a Steam Turbine in a Power Plant Coking and Fire in a Refinery Hydroprocessing Vessel |
Aptech Engineering Services, Inc. has been acquired by Intertek USA, Inc. Please visit us at www.intertek.com/aptech. Fire in Gas Turbine-Driven Natural Gas Compressor A fire broke out in a gas turbine-driven natural gas compressor, causing damage to the unit and to adjacent equipment. APTECH was hired to determine the root cause of the fire and to itemize the extent of damage produced by this fire. Our evaluation involved site inspections, interviews with site personnel, field metallurgical testing (e.g., metallurgical replication, hardness measurements, etc.), reviewing the lubrication system designs and fire suppression, and a nondestructive laboratory failure investigation of a fractured lube oil line. We determined that an unnoticed oil line vibration caused fatigue at a fitting and the oil line ruptured. The oil impinging on the hot section of the gas turbine ignited and caused the fire. APTECH provided expert opinions regarding the cause of the fire, the extent of subsequent damage, and the repair cost estimates.
|
||||||||||||||||||||||||||||
| APTECH Main office location is in Sunnyvale, California — in the heart of Silicon Valley, San Francisco Bay Area. 601 W. California Ave., Sunnyvale, California 94086-4831 and P.O. Box 3440, Sunnyvale, CA 94088-3440 (408) 745-7000 | ||
| APTECH Corp > Forensic Engineering Services Group > Past Case Summaries Case Index | ||
|
|
||