Similar Cases: Fire in Gas Turbine-Driven Natural Gas Compressor Catastrophic Failure of a Steam Turbine in a Power Plant Steam Turbine Failure and Explosion Failure of Roller Bearings in a Radial Kaplan Hydroelectric Turbine |
Gas Turbine Fire A gas turbine was exposed to a fire that was fed by a leak in the lubricating oil supply line. APTECH was retained to evaluate the condition of the turbine rotor with respect to the possible loss of strength and material embrittlement. Our evaluation of the material indicated that the time/temperature fire exposure history would not result in degradation of the rotor's material properties. We concluded that the rotor was not adversely affected by the fire, and recommended that dimensional checks of the rotor be performed.
|
||||||||||||||||||||||||||||