Similar Cases: Power Plant Damage Due to Collapse of Underground Cooling Pipes Power Plant Cycling and Derating Analysis Catastrophic Failure of a Steam Turbine in a Power Plant |
Aptech Engineering Services, Inc. has been acquired by Intertek USA, Inc. Please visit us at www.intertek.com/aptech. Catastrophic Failure of High Energy Power Plant Piping (Mohave Plant) A 30-inch diameter hot reheat steam pipe, operating at 1000°F and 600 psig, ruptured without warning in a fossil power plant. This accident caused numerous fatalities and major property loss. APTECH was hired by one of the defendants to investigate the failure of the pipe. APTECH performed a detailed stress analysis of the as-built line configuration and evaluated the material properties and the likelihood of creep damage under stresses sustained during normal operation. APTECH also investigated maintenance practices over an extended period at the plant prior to the failure. We concluded that the failure was caused by creep damage in local regions adjacent to the heat affected zone of the long seam weld.
|
||||||||||||||||||||||||||||
| APTECH Main office location is in Sunnyvale, California — in the heart of Silicon Valley, San Francisco Bay Area. 601 W. California Ave., Sunnyvale, California 94086-4831 and P.O. Box 3440, Sunnyvale, CA 94088-3440 (408) 745-7000 | ||
| APTECH Corp > Forensic Engineering Services Group > Past Case Summaries Case Index | ||
|
|
||