Similar Cases: Structural Steel Weld Quality Audit Cracking in the Welds in Wide Flange Column Connections in Structural Steel Suitability-for-Service Evaluation of Seam Welded Heating Boilers Analysis of Moment-Resisting Welds After The Northridge Earthquake Long Span Steel Girders in Sony's Metreon Center Power Plant Damage Due to Collapse of Underground Cooling Pipes |
Aptech Engineering Services, Inc. has been acquired by Intertek USA, Inc. Please visit us at www.intertek.com/aptech. Water Treatment Plant Collapse A water treatment plant in Southern California used a parallel arrangement of three boat clarifiers to separate sludge from the effluent. The clarifiers are so-named because they are shaped like the hull of a boat. The clarifiers were suspended in side-by-side oval-shaped oxidation ditches. During normal operation, the water level in the clarifiers is the same as that in the surrounding ditches. In June 1997 a contractor was flow testing the clarifiers after the ditch had been drained when the boat clarifier's support structure suddenly collapsed. Aptech was hired by the insurance adjuster to find the cause of this incident. Our initial examination and interviews clearly indicated that the collapse occurred as water was collecting in the bow of the clarifier while there was no water in the surrounding ditch. The operation manual contained warnings regarding the need to maintain equal water levels in the boat clarifier and its ditch. We analyzed the support structure and found that it could not support the clarifier without the buoyancy provided by water in the ditch. We also found metallurgical flaws in the welds in the support beams, which made the clarifier even more susceptible to collapse. The collapse occurred when water backed up into the clarifier with the empty ditch from an adjacent clarifier that was being filled. The contractor had improperly left a piping valve open during the flow testing. This accident could have been avoided if the plant designers had placed a check valve in the outlet piping of the clarifier. This would have prevented backflow from any of the boat clarifiers while they were being filled with water.
|
||||||||||||||||||||||||||||||||||
| APTECH Main office location is in Sunnyvale, California — in the heart of Silicon Valley, San Francisco Bay Area. 601 W. California Ave., Sunnyvale, California 94086-4831 and P.O. Box 3440, Sunnyvale, CA 94088-3440 (408) 745-7000 | ||
| APTECH Corp > Forensic Engineering Services Group > Past Case Summaries Case Index | ||
|
|
||